Document name iPECS UCP/EMG80 – Loop Disconnect Clear (Line Lockup) on Analogue Lines Author  Anita Robson Publish Date 19112018 Version  1.0

 

 

1. Version Information 

 

 

Date Author Update Information  Version 19/11/2018 Anita Robson 1st draft 1.0

 

 

2. Document Purpose & History

 

 

 

This document is intended to provide the reader with the necessary steps to set Loop Disconnect Clear on Analogue lines

 

 

Loop Disconnect Clear (Line lockup) on Analogue  Lines

 

 

If you have analogue lines that are not clearing down after a call, you need to adjust the Loop Disconnect Clear timer.

 

PGM 141

 

 

 

Set Order 7 – Open Loop Detect Timer to 5 (500ms).  You also need to ensure the network provider has set the lines to 800ms at their end.