Document name 1048iLSS on UCP Author  Llewellyn Carson Publish Date 04/01/2022 Version  1.0 Reference  

 

 

1. Version Information 

 

Date Author Update Information  Version 04/01/2022 Llewellyn Carson 04/01/2022 Ver1.0                

 

This document is intended to provide the reader with information on installing a 1048iLSS onto a UCP.

 

1048iLSS on UCP 

 

 

The 1048iLSS is supported on Unified 5.0 software or higher. 

 

1.) Please note from the below image the switch that needs to be switched depending on POE installed.

 

 

  

 

2.) The below image shows iLSS with POE being used and not Power.

 

 

3.) Below image shows iLSS with Power adaptor being used and not POE. (Order the power adaptor separately)

 

 

 

 4.) Flexible Buttons – PGM 115/129

 

Selecting Flex Buttons will display the Flex buttons data input page. Enter a valid Station range and click [Load] to enter Flex button data. For convenience, the copy, paste, and drag is available to enter or modify data. Please click [Save] button after entering or modifying data to apply.

You can set the initial system default value if there is no assignment in Flexible Button Default Table (239) and Preset Flexible Button Default (240) by clicking [Default Value]. Otherwise, you can set the flexible button value according to Flexible Button Default Table (239) and Preset Flexible Button Default (240) by clicking on it.

 

 

 

Flex Buttons Assignment

 

Each Flex button for each iPECS IP and LDP Phone and DSS Console can be assigned a function (TYPE) as below. After selecting the Type for a button, enter the value, if required. The types available from the drop-down menu are shown are shown in Table below. In addition, for the LIP Phone models 8040, 8050, 9070, 9071 and the LSS Console models, a label can be assigned that is used as the designation for the button in the LCD of the phone.

 

 

FLEX BUTTON TYPE & VALUE

 

TYPE

REMARK

N/A

Empty (unassigned), may be defined by the user.

 

CO Line

Assigns button to access a defined CO/IP line.

CO Group

Assigns button to access a free line in the CO/IP

Group.

 

Loop

Assigns button to access a loop line.

 

Station Number

Assigns button as DSS/BLF for the assigned station number.

 

Programming

(Numbering Plan)

Assigns button to dial a code from the Flexible Numbering Plan, see Appendix section.

 

Programming (PGM)

Assigns button to perform a User Program function from the Fixed Numbering Plan, Appendix section.

 

Station Speed

Station Speed Dial bin.

 

System Speed

System Speed Dial bin.

Net Station

Refer to Network Numbering Plan Table – PGM 324.

 

U-Loop

U-Loop button for call wait of internal & external call

 

 

Dial Digit

The user can assign the desired number on Flexible button by selecting ‘Dial Digit’ in the field of Type. The user can make a call by pressing the assigned flexible button.